Product Attributes *** 3 WEEK LEAD TYPICAL *** SENSING ELEMENT THERMAL MASS PIPE SIZE 01.00 - 20.00 IN. OUTPUT SIGNAL MUST SPECIFY
Configure Product - FT2A-IN--05P-SS-ST-E1-B0-G1 Expand All Flow Body: - [05P] = 1/2" Male NPT Ends, 12" Face To Face, 316SS Body $572.75 [05P] = 1/2" Male NPT Ends, 12" Face To Face, 316SS Body [075P] = 3/4" Male NPT Ends, 12" Face To Face, 316SS Body [10P] = 1" Male NPT Ends, 12" Face To Face [125P] = 1 1/4" Male NPT Ends, 12" Face To Face, 316SS Body [15P] = 1 1/2" Male NPT Ends, 12" Face To Face, 316SS Body [20P] = 2" Male NPT Ends, 12" Face To Face, 316SS Body [25P] = 2 1/2" Male NPT Ends, 18" Face To Face, 316SS Body [30P] = 3" Male NPT Ends, 18" Face to Face, 316SS Body [05F] = 1/2" 150 lb RF Flanges, 12" Face to Face, 316SS Body [075F] = 3/4" 150 lb RF Flanges, 12" Face to Face, 316SS Body [10F] = 1" 150 lb RF Flanges, 12" Face to Face, 316SS Body [125F] = 1 1/4" 150 lb RF Flanges, 12" Face to Face, 316SS Body [15F] = 1 1/2" 150 lb RF Flanges, 12" Face to Face, 316SS Body [20F] = 2" 150 lb RF Flanges, 12" Face to Face, 316SS Body [25F] = 2 1/2" 150 lb RF Flanges, 18" Face to Face, 316SS Body [30F] = 3" 150 lb RF Flanges, 18" Face To Face, 316SS Body [40F] = 4" 150 lb RF Flanges, 18" Face to Face, 316SS Body [60F] = 6" 150 lb RF Flanges, 24" Face to Face, 316SS Body [20PC] = 2" Male NPT Ends, 12" Face to Face, Carbon Steel [25PC] = 2 1/2" Male NPT Ends, 18" Face to Face, Carbon Steel [30PC] = 3" Male NPT Ends, 18" Face to Face, Carbon Steel [20FC] = 2" 150 lb RF Flanges, 12" Face to Face, Carbon Steel [25FC] = 2 1/2" 150 lb RF Flanges, 18" Face to Face, Carbon Steel [30FC] = 3" 150 lb RF Flanges, 18" Face to Face, Carbon Steel [40FC] = 4" 150 lb RF Flanges, 18" Face to Face, Carbon Steel [60FC] = 6" 150 lb RF Flanges, 24" Face to Face, Carbon Steel Sensor Material: - [SS] = 316 Stainless Steel Sensor & Flow Body [SS] = 316 Stainless Steel Sensor & Flow Body [SH] = 316SS Flow Body With Hastelloy C276 Sensor Requires E3 or E4 Enclosure Sensor Type: - [ST] = Standard Sensor - -40 to 250F [ST] = Standard Sensor - -40 to 250F [HT] = High Temperature Sensor (32-650F), AIR ONLY Requires E3 or E4 Enclosure Enclosure/Power: - [E1] = Local NEMA 4X Enclosure, 24 VDC [E1] = Local NEMA 4X Enclosure, 24 VDC [E2] = Local NEMA 4X Enclosure, 85-264 VAC [E3] = Remote J-Box, 24 VDC Cable Sold Separately [E4] = Remote J-Box, 85-264 VAC Bus Options: - [B0] = No Communications Bus [B0] = No Communications Bus [MB] = Modbus (RS485) [BN] = BACnet MS/TP (RS485) [BD] = DeviceNet [BP] = Profibus-DP [BE] = Ethernet Modbus TCP Calibration: - [G1] = Air, N2: MF Less Than 1200 SCFM $750.50 [G1] = Air, N2: MF Less Than 1200 SCFM [G2] = Air, N2: MF Above 1200 SCFM [G3] = Air, CO2, H2, CH4, Natural Gas, O2: MF Less Than 1000 SCFM [G4] = Air, CO2, H2, CH4, Natural Gas, O2: MF Above 1000 SCFM [G5] = CO, He, Ammonia, Propane: MF Less Than 700 SCFM [G6] = CO, He, Ammonia, Propane: MF Above 700 SCFM [G7] = Biogas, Digester Gas, Flare Gas, Flash Gas, Vent Gas Enter Pipe Schedule Pipe Schedule: - Enter Pipe Schedule Please Enter Typical Flow Rate Flow Rate: - Please Enter Typical Flow Rate FT2A-IN--05P-SS-ST-E1-B0-G1 Log in or call for pricing